{ "culture": "en-US", "name": "", "guid": "", "catalogPath": "", "snippet": "Gravity Flow Sewage Pipes. This includes mains, inlet laterals, and building laterals for sanitary, combined, and storm water.", "description": "
//Last updated 11/6/2024 by Robert Watt<\/SPAN><\/P> OBJECTID - See Esri documentation<\/SPAN><\/P><\/LI> FACILITYID - Legacy \"Unique\" ID. Not maintained for new assets.<\/SPAN><\/P><\/LI> FROMMH - Upstream Structure Asset ID. May be a Manhole, Inlet, or text description of some other source.<\/SPAN><\/P><\/LI> TOMH - Downstream Structure Asset ID. May be a Manhole, Outlet, or text description of some other source.<\/SPAN><\/P><\/LI> INSTALLDATE - Date of installation. May be the first of a year or month when the specifics are unknown.<\/SPAN><\/P><\/LI> MATERIAL - The material of the majority of the pipe.<\/SPAN><\/P><\/LI> MEASUREMENT1 - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> MEASUREMENT2 - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> NOMINALDIAMETER - the \"nominal\" pipe diameter in inches.<\/SPAN><\/P><\/LI> MAINSHAPE - The shape of the pipe. Usually round, sometimes egg or other. Note that culverts are separated in their own layer regardless of shape.<\/SPAN><\/P><\/LI> LINEDYEAR - The year in YYYY of the most recent pipelining.<\/SPAN><\/P><\/LI> LINERTYPE - The variety of liner used in LINEDYEAR.<\/SPAN><\/P><\/LI> WATERTYPE - The variety of water conveyed by the main. <\/SPAN>'Abandoned' type pipe to be marked as LifeStatus: abandoned, and water type updated to reflect the water type formerly conveyed.<\/SPAN><\/P><\/LI> ENABLED - See Esri documentation. <\/SPAN>To be replaced by LifeCycleStatus.<\/SPAN><\/P><\/LI> ACTIVEFLAG<\/SPAN> <\/SPAN>- See Esri documentation. <\/SPAN>To be replaced by LifeCycleStatus.<\/SPAN><\/P><\/LI> OWNEDBY - Who owns this asset?<\/SPAN><\/P><\/LI> MAINTBY - Who maintains this asset?<\/SPAN><\/P><\/LI> SUMFLOW - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> LASTUPDATE - System Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI> LASTEDITOR - System Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI> DOWNELEV - The Invert elevation of the downstream end of the pipe. Ostensibly in NAVD88 feet.<\/SPAN><\/P><\/LI> UPELEV - The Invert elevation of the upstream end of the pipe. Ostensibly in NAVD88 feet.<\/SPAN><\/P><\/LI> SLOPE - The slope of the pipe (UPELEV-DOWNELEV)/LENGTH. Positive slope indicates UPELEV is higher than DOWNELEV.<\/SPAN><\/P><\/LI> UNDERDRAIN - True indicates that this pipe is an underdrain.<\/SPAN><\/P><\/LI> WSEID - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> TEMPID - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> Upstream_Depth - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> DwnStream_Depth - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> created_user - system Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI> created_date - system Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI> last_edited_user - legacy editor tracking field. <\/SPAN><\/P><\/LI> last_edited_date - legacy editor tracking field.<\/SPAN><\/P><\/LI> SYSTEM_ID -<\/SPAN> UNKNOWN<\/SPAN><\/P><\/LI> PipeDiam_Ft - Pipe Diameter in Feet. <\/SPAN>Candidate for deletion if this is a duplication of NOMINALDIAMETER.<\/SPAN><\/P><\/LI> TOMH_RIM - The elevation of the downstream structure rim. <\/SPAN>Candidate for deletion as the system of record for this info is the structure's feature.<\/SPAN><\/P><\/LI> PipeLength - the length of the pipe in feet<\/SPAN><\/P><\/LI> VerificationStatus - the last known field verification status, indicating the quality of the GIS data.<\/SPAN><\/P><\/LI> Notes - Text notes about the pipe.<\/SPAN><\/P><\/LI> LineType - The structural role that the pipe plays. <\/SPAN>This may be worth reconsidering/defining. What value does it add?<\/SPAN><\/P><\/LI> CoF - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> PoF - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI> InletOff - The distance from structure invert/ sump to pipe inlet invert. In decimal feet. This value is used for modeling in SWMM. <\/SPAN>Candidate for deletion as this is a derivative of the more definitive structure invert and pipe invert(s).<\/SPAN><\/P><\/LI> OutOff - The distance from structure invert/ sump to pipe outlet invert. In decimal feet. This value is used for modeling in SWMM. <\/SPAN>Candidate for deletion as this is a derivative of the more definitive structure invert and pipe invert(s).<\/SPAN><\/P><\/LI> INSTALLYR - Installation year. <\/SPAN>Candidate for delation as this is a derivative of the more definitive INSTALLDATE.<\/SPAN><\/P><\/LI> HostPipeYr - In lined or inserted pipe, this is the original (host) pipe's installation year. <\/SPAN>Why is this not a date?<\/SPAN><\/P><\/LI> HostPipeMat - In lined or inserted pipe, this is the original (host) pipe's material.<\/SPAN><\/P><\/LI> GlobalID - See Esri Documentation.<\/SPAN><\/P><\/LI> Asset ID - The modern unique ID used to communicate features. This cannot be changed as it is the child ID used in VueWorks to connect WorkOrders, inspections, and documents.<\/SPAN><\/P><\/LI> REPAIRDATE - The most recent dates when repairs were conducted on this feature.<\/SPAN><\/P><\/LI> REPAIRDESC - A brief description of each repair made.<\/SPAN><\/P><\/LI> LifeStatus - Is this pipe active or abandoned? Removed or left in the ground?<\/SPAN><\/P><\/LI> Shape_Length - See Esri Documentation.<\/SPAN><\/P><\/LI> SHAPE - See Esri Documentation.<\/SPAN><\/P><\/LI><\/UL><\/DIV><\/DIV><\/DIV>",
"summary": "Gravity Flow Sewage Pipes. This includes mains, inlet laterals, and building laterals for sanitary, combined, and storm water.",
"title": "infrastructure.PUBLICWORKS.ssGravityMain",
"tags": [
"Sewer"
],
"type": "",
"typeKeywords": [],
"thumbnail": "",
"url": "",
"minScale": 150000000,
"maxScale": 5000,
"spatialReference": "",
"accessInformation": "",
"licenseInfo": ""
}