{ "culture": "en-US", "name": "", "guid": "", "catalogPath": "", "snippet": "Gravity Flow Sewage Pipes. This includes mains, inlet laterals, and building laterals for sanitary, combined, and storm water.", "description": "

//Last updated 11/6/2024 by Robert Watt<\/SPAN><\/P>

  • OBJECTID - See Esri documentation<\/SPAN><\/P><\/LI>

  • FACILITYID - Legacy \"Unique\" ID. Not maintained for new assets.<\/SPAN><\/P><\/LI>

  • FROMMH - Upstream Structure Asset ID. May be a Manhole, Inlet, or text description of some other source.<\/SPAN><\/P><\/LI>

  • TOMH - Downstream Structure Asset ID. May be a Manhole, Outlet, or text description of some other source.<\/SPAN><\/P><\/LI>

  • INSTALLDATE - Date of installation. May be the first of a year or month when the specifics are unknown.<\/SPAN><\/P><\/LI>

  • MATERIAL - The material of the majority of the pipe.<\/SPAN><\/P><\/LI>

  • MEASUREMENT1 - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • MEASUREMENT2 - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • NOMINALDIAMETER - the \"nominal\" pipe diameter in inches.<\/SPAN><\/P><\/LI>

  • MAINSHAPE - The shape of the pipe. Usually round, sometimes egg or other. Note that culverts are separated in their own layer regardless of shape.<\/SPAN><\/P><\/LI>

  • LINEDYEAR - The year in YYYY of the most recent pipelining.<\/SPAN><\/P><\/LI>

  • LINERTYPE - The variety of liner used in LINEDYEAR.<\/SPAN><\/P><\/LI>

  • WATERTYPE - The variety of water conveyed by the main. <\/SPAN>'Abandoned' type pipe to be marked as LifeStatus: abandoned, and water type updated to reflect the water type formerly conveyed.<\/SPAN><\/P><\/LI>

  • ENABLED - See Esri documentation. <\/SPAN>To be replaced by LifeCycleStatus.<\/SPAN><\/P><\/LI>

  • ACTIVEFLAG<\/SPAN> <\/SPAN>- See Esri documentation. <\/SPAN>To be replaced by LifeCycleStatus.<\/SPAN><\/P><\/LI>

  • OWNEDBY - Who owns this asset?<\/SPAN><\/P><\/LI>

  • MAINTBY - Who maintains this asset?<\/SPAN><\/P><\/LI>

  • SUMFLOW - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • LASTUPDATE - System Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI>

  • LASTEDITOR - System Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI>

  • DOWNELEV - The Invert elevation of the downstream end of the pipe. Ostensibly in NAVD88 feet.<\/SPAN><\/P><\/LI>

  • UPELEV - The Invert elevation of the upstream end of the pipe. Ostensibly in NAVD88 feet.<\/SPAN><\/P><\/LI>

  • SLOPE - The slope of the pipe (UPELEV-DOWNELEV)/LENGTH. Positive slope indicates UPELEV is higher than DOWNELEV.<\/SPAN><\/P><\/LI>

  • UNDERDRAIN - True indicates that this pipe is an underdrain.<\/SPAN><\/P><\/LI>

  • WSEID - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • TEMPID - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • Upstream_Depth - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • DwnStream_Depth - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • created_user - system Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI>

  • created_date - system Maintained. See Esri Documentation.<\/SPAN><\/P><\/LI>

  • last_edited_user - legacy editor tracking field. <\/SPAN><\/P><\/LI>

  • last_edited_date - legacy editor tracking field.<\/SPAN><\/P><\/LI>

  • SYSTEM_ID -<\/SPAN> UNKNOWN<\/SPAN><\/P><\/LI>

  • PipeDiam_Ft - Pipe Diameter in Feet. <\/SPAN>Candidate for deletion if this is a duplication of NOMINALDIAMETER.<\/SPAN><\/P><\/LI>

  • TOMH_RIM - The elevation of the downstream structure rim. <\/SPAN>Candidate for deletion as the system of record for this info is the structure's feature.<\/SPAN><\/P><\/LI>

  • PipeLength - the length of the pipe in feet<\/SPAN><\/P><\/LI>

  • VerificationStatus - the last known field verification status, indicating the quality of the GIS data.<\/SPAN><\/P><\/LI>

  • Notes - Text notes about the pipe.<\/SPAN><\/P><\/LI>

  • LineType - The structural role that the pipe plays. <\/SPAN>This may be worth reconsidering/defining. What value does it add?<\/SPAN><\/P><\/LI>

  • CoF - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • PoF - <\/SPAN>UNKNOWN<\/SPAN><\/P><\/LI>

  • InletOff - The distance from structure invert/ sump to pipe inlet invert. In decimal feet. This value is used for modeling in SWMM. <\/SPAN>Candidate for deletion as this is a derivative of the more definitive structure invert and pipe invert(s).<\/SPAN><\/P><\/LI>

  • OutOff - The distance from structure invert/ sump to pipe outlet invert. In decimal feet. This value is used for modeling in SWMM. <\/SPAN>Candidate for deletion as this is a derivative of the more definitive structure invert and pipe invert(s).<\/SPAN><\/P><\/LI>

  • INSTALLYR - Installation year. <\/SPAN>Candidate for delation as this is a derivative of the more definitive INSTALLDATE.<\/SPAN><\/P><\/LI>

  • HostPipeYr - In lined or inserted pipe, this is the original (host) pipe's installation year. <\/SPAN>Why is this not a date?<\/SPAN><\/P><\/LI>

  • HostPipeMat - In lined or inserted pipe, this is the original (host) pipe's material.<\/SPAN><\/P><\/LI>

  • GlobalID - See Esri Documentation.<\/SPAN><\/P><\/LI>

  • Asset ID - The modern unique ID used to communicate features. This cannot be changed as it is the child ID used in VueWorks to connect WorkOrders, inspections, and documents.<\/SPAN><\/P><\/LI>

  • REPAIRDATE - The most recent dates when repairs were conducted on this feature.<\/SPAN><\/P><\/LI>

  • REPAIRDESC - A brief description of each repair made.<\/SPAN><\/P><\/LI>

  • LifeStatus - Is this pipe active or abandoned? Removed or left in the ground?<\/SPAN><\/P><\/LI>

  • Shape_Length - See Esri Documentation.<\/SPAN><\/P><\/LI>

  • SHAPE - See Esri Documentation.<\/SPAN><\/P><\/LI><\/UL><\/DIV><\/DIV><\/DIV>", "summary": "Gravity Flow Sewage Pipes. This includes mains, inlet laterals, and building laterals for sanitary, combined, and storm water.", "title": "infrastructure.PUBLICWORKS.ssGravityMain", "tags": [ "Sewer" ], "type": "", "typeKeywords": [], "thumbnail": "", "url": "", "minScale": 150000000, "maxScale": 5000, "spatialReference": "", "accessInformation": "", "licenseInfo": "" }